Large Flow Rate Double Suction 75HP Power Pump for Chilled Water

Max.Head: 110m-150m
Max.Capacity: >400 L/min
Driving Type: Motor
Material: Cast Iron
Structure: Single-stage Pump
Assembly: Pipeline Pump
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
QS
Power
Electric
Start Up
Electric Pump
Type
Horizontal Split Case Pump
Application
Clarified Water Pump, Sewage Pump, Oil Transfer Pump, Chemical Pump, Large Flow Pump
Industry
Mechanical Pump
Media
Sea Water Pump
Performance
No Leakage Pump
Theory
Electromagnetic Pump
75horse Power Pump Condition
New Horizontal Split Case Pump
Driver
75horse Power Pump for Chilled Water
Certificate
ISO, Ce, SGS. TUV.BV
Warranty
12 Months Except Flow Parts
Size
6"-48"
Flow
120-10000m3/H
Head
8-108m
Feature
Large Volume Water Pump
OEM
Available
Pump Type
Centrifugal Water Pump
Transport Package
Fumigated Wooden Case
Specification
Class One
Trademark
An Pump
Origin
China
HS Code
841370
Production Capacity
880 Sets/Month

Product Description

Large flow rate 75horse power pump for chilled water 

Large Flow Rate Double Suction 75HP Power Pump for Chilled Water


Summarize:
Model QS Single stage centrifugal double suction split case 75horse power pump for chilled water is a single-stage double-suction horizontal split centrifugal pump and used to transport pure water and the liquid of both physical and chemical nature similar to those of water, the maximum temperature of which must not be over 80ºC , suitable for water supply and drainage in factories, mines, cities and electric stations, waterlogged land drainage and irrigation of farming land and carious hydraulic projects.
 
Application for 75horse power pump for chilled water 
 Aerospace                          Oil & Gas
 Building industry                 Power Station
 Chemical                            Petro-Chemical
 General Industry                Pharmaceutical
 Marine                                Pulp & Paper
 Mining & Aggregate            Water & Waste water
 
Advantage:
20 years in producing 75horse power pump for chilled water   
Independent Design
advanced technology from Australia, Canada, America
Specialized Test Equipment
Anti-rust treatment casting
Supply reasonable suggestion for choosing pumps
OEM available

Pump Structure 
1. 75horse power pump for chilled water Casing
The volute casing is split on the horizontal centerline with the suction and discharge nozzle cast integral with the pump casing. The upper casing is accurately located on the lower half by the use of dowel pins. The upper casing can be removed to inspect the interior of the pump without disturbing the pipe connections or pump alignment. The suction and discharge flanges contain tapped holes for vacuum and pressure gauge. At the bottom of the flanges, there are tapped plugs for water drainage. 
2. Impeller
The impeller is static-balance calibrated, fixed with the muff and the muff nuts in both sides and its axial position can be adjusted via the nuts and axial force gets balanced by means of the symmetrical arrangement of its blades, there may be residual axial force which is borne by the bearing at the axle end.
3. Shaft
The pump shaft is supported by two single-column centripetal ball bearings, which are mounted inside of the bearing body on both ends of the pump and lubricated with grease. The dual-suction seal ring is used to reduce the leak at the impeller
4. Seal Type
There is gland seal type and mechanical seal type.
 
Direction of Rotation
Single stage centrifugal double suction split case cooling tower cryogenic pump moves CW viewing from the clutch to it. The pump moving CCW can also be produced.
  
Material of 75horse power pump for chilled water 
Single stage centrifugal double suction split case cooling tower cryogenic pump general material is cast iron, main include pump casing, pump cover, impeller, seal ring and shaft sleeve, shaft is carbon steel. We could also produce as your requirements, such as nodular cast iron, cast steel, bronze and stainless steel etc.

RFQ:
Single stage centrifugal double suction split case 75horse power pump for chilled water power loss
There only a part of the mechanical power of the centrifugal pump getting from the driver equipment, convert to the centrifugal power and then delivered to the liquid power. The another part was loss. The reasons are below:
1. Hydraulic loss: Created for the liquid impact, vortex and friction in the pump. The impact and vortex hydraulic loss is because of the the liquid change the flow direction. Besides, when the liquid flow, it will have friction when meet the pump passageway.This kind of loss depend on the length, volume, shape, and surface roughness of the passageway and the liquid flow speed and other character.
2. Volume loss: It resulted for the powered liquid will channeling are leakage. The general pump volume efficiency is 0.93~0.98%. Improve the seal ring and shaft seal construction, can reduce the volume loss and increase the volume efficiency.
3. Mechanical loss: It is caused by the friction of liquid and impeller plate surface, also named dick friction loss of impeller, and the pump shaft friction when rotated in the packing, bearing, balancing parts and other mechanical parts. 



FAQ 

Q1. Are you a manufacturer?
Yes, we have been in centrifugal pumps manufacturing and marketing industry over 32 years.
 
Q2What markets do your pumps export to?
Europe, North & South America, South-East Asia, Africa, Oceanica, Middle East countries. Our overseas agent in Italy, Russia, America and Africa are gradually improving.
 
Q3. What information should I let you know if I want to get a quotation?
Please let us know the pump capacity, head, medium, operation situation, quantity, etc. As much as your provide, the precision and accurate model selection.

 
Q4. Is it available to print our own brand on the pump?
Totally acceptable as international rules.
 
Q5. How can I get the price of your pump?
You can connect with us through any of the following contact information. Our personalized service person will respond you within 24 hours.
Large Flow Rate Double Suction 75HP Power Pump for Chilled Water


 
Contact information


Large Flow Rate Double Suction 75HP Power Pump for Chilled Water

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 14001
OEM/ODM Availability
Yes